Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Rev. Fac. Med. UNAM ; 66(5): 24-34, sep.-oct. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535214

ABSTRACT

Resumen Los "bezoar" son conglomerados de materiales no comestibles ingeridos voluntaria o involuntariamente, no digeridos e incapaces de transitar por el tracto intestinal. Principalmente afectan a jóvenes mujeres o adolescentes que presentan el fenómeno llamado "pica", y a pesar de que se ha registrado una alta prevalencia de este fenómeno en pacientes con enfermedad renal crónica (ERC), ha sido poco estudiado. Caso clínico: Paciente del sexo masculino de 35 años de edad que cursa con ERC KDIGO-5 en tratamiento con diálisis peritoneal; se obtiene el hallazgo de "bezoar plástico" transoperatorio (laparotomia por oclusión intestinal) a 10 cm de la válvula ileocecal. El paciente fallece por complicaciones de la patología de origen. Se plantea la necesidad de realizar la búsqueda de comportamientos en pacientes con ERC, que indiquen al cirujano la sospecha, dado que los pacientes generalmente ocultan u omiten referir sobre la ingesta de material extraño.


Abstract The "bezoar" are conglomerates of inedible materials ingested voluntarily or involuntarily, which are not digested and are unable to pass through the intestinal tract. They mainly affect young women or adolescents who present the phenomenon called "pica", despite the fact that a high prevalence of this phenomenon of "pica" has been registered in patients with chronic kidney disease, it has been little studied. Clinical case: A 35-year-old male with CKD KDIGO-5 undergoing peritoneal dialysis treatment, which was found to have a transoperative "plastic bezoar" (laparotomy for intestinal occlusion) 10 cm from the ileocecal valve. The patient died due to complications of his pathology. Discussion: the clinical case raises the need to search for behaviors such as pica in patients with CKD, as well as to develop the suspicion to the surgeon, since patients generally hide or ignore reporting foreign material phagia.

2.
Rev. colomb. cir ; 38(1): 22-29, 20221230. fig
Article in Spanish | LILACS | ID: biblio-1415226

ABSTRACT

La historia del plástico se remonta a mediados del siglo XIX, y se considera que se origina por el interés de cambiar la materia prima en la fabricación de las bolas de billar, hechas originalmente en marfil. Desde entonces y a lo largo de muchos años, el polietileno, cloruro de polivinilo, poliestireno, polimetilmetacrilato, polietilentereftalato (PET), las poliamidas y otras sustancias similares han formado parte del día a día de la humanidad, a tal punto que algunos expertos en el tema consideran que estamos viviendo "La era del plástico". Todos los insumos y elementos plásticos han facilitado la vida, pero también han causado una gran contaminación ambiental que afecta la fauna, la flora y por supuesto al ser humano. La gran mayoría de los países han comprendido esta situación y han promulgado leyes o diseñado estrategias con el fin de contener el uso inadecuado y la generación de la contaminación causada por el plástico. Muchas de estas medidas han sido frenadas e incluso revertidas debido a la pandemia por COVID-19, que además de todas las afectaciones conocidas, ha causado un desmesurado incremento en el uso de materiales plásticos, como los elementos de protección personal, con el consecuente aumento de la contaminación y los riesgos que esta genera en la salud humana. Estos temas son tratados en este artículo, con el fin de concientizar al personal médico y a la población en general


The history of plastic dates back to the mid-nineteenth century, and it is considered that it originates from the interest in changing the raw material in the manufacture of billiard balls, originally made of ivory. Since then and for many years, polyethylene, polyvinyl chloride, polystyrene, polymethyl methacrylate, polyethylene terephthalate (PET), polyamides and other similar substances have been part of humanity's daily life, to the point that some consider that we are living 'The era of plastic'.All the inputs and plastic elements have made life easier, but they have also caused great environmental pollution that affects fauna and flora, and of course the human being. The vast majority of countries have understood this situation, have enacted laws and designed strategies in order to contain the inappropriate use and generation of pollution caused by plastic.Many of these measures have been stopped and even reversed due to the COVID-19 pandemic, which in addition to all the known effects, has caused a disproportionate increase in the use of plastic materials, such as personal protection elements with the consequent increase in pollution and the risks it generates for human health. These issues are addressed in this article, in order to raise awareness among medical personnel and the general population


Subject(s)
Humans , Plastics , Environmental Pollution , Legislation , Pandemics , COVID-19
3.
Rev. argent. cir. plást ; 28(1): 13-19, 20220000. fig, tab
Article in Spanish | LILACS, BINACIS | ID: biblio-1392216

ABSTRACT

Las lesiones de punta de dedo son comunes en pacientes pediátricos que acuden a salas de Emergencia; son causadas por accidentes en el hogar y con aplastamiento en puerta como principal mecanismo de trauma. El tratamiento se realiza individualizado por cirujanos plásticos y cirujanos pediátricos en dependencia de la herida y el compromiso tisular. El propósito de este estudio es describir el manejo de pacientes con lesiones de punta de dedo en un centro pediátrico. Se realizó un análisis de historias clínicas en el período entre enero 2015 y diciembre 2020, se evaluaron 228 pacientes atendidos en el Hospital de Niños Dr. Roberto Gilbert Elizalde, en Guayaquil, Ecuador. Los resultados incluyen un predominio de pacientes en edad preescolar (67%), masculinos (56%) y de mano derecha (53%). Los dedos más afectados fueron el medio y anular. Los procedimientos fueron realizados por cirujanos plásticos (55%) y la técnica electiva fue bajo anestesia general. La extensión del daño involucró tejidos blandos (92%), avulsión de uña (29%) y fracturas asociadas (15%). El 3% de los pacientes presentó complicaciones que requirieron seguimiento. El tipo de reparo se seleccionó en dependencia de la extensión de la herida, se realizaron suturas simples (37%) y suturas complejas con reparo de la uña (27%). Nuestros datos son similares a los descritos en la literatura internacional, con buenos resultados a largo plazo, menor tasa de complicaciones y respuestas similares en los reparos realizados por cirujanos plásticos y cirujanos pediatras.


Fingertip injuries are common in pediatric patients who present to the emergency room. They are usually caused by accidents at home, being door-crush the main mechanism. Treatment is performed on an individual basis, by a Plastic or General Pediatric Surgeon, according to the wound findings and tissue involvement. The purpose of this study is to describe the management on a pediatric center in patients with a fingertip wound. A descriptive and retrospective analysis of medical records was carried out from January 2015 until December 2020. In this period 228 patients were seen in the Dr. Roberto Gilbert Elizalde Children´s Hospital in Guayaquil, Ecuador. A high incidence was found in the preschool age with 67% of cases. The injuries were more common in males (56 %) and more predominant on the right hand (53%). The most affected fingers were the middle and annular. Procedures were mostly performed by Pediatric Surgeons (55%) and the elective technique was under general anesthesia. Damage extension of the fingertip included soft tissues in 92% of patients, nail avulsion in 29% and associated fractures in 15%. Only 3% of patients developed complications that required follow up. The type of repair was selected according to the extension of the injury. Mostly simple sutures (37%) and complex sutures with nail repair (27%)were used.Our data is similar to the one found in international literature, with good long-term outcomes, minor complications and similar results when the repair was performed by a Plastic or Pediatric surgeon


Subject(s)
Humans , Infant , Child, Preschool , Child , Adolescent , Wounds and Injuries/therapy , Epidemiology, Descriptive , Retrospective Studies , Finger Injuries/therapy , Fingers/surgery , Crush Injuries/therapy
4.
Rev. biol. trop ; 69(4)dic. 2021.
Article in Spanish | LILACS, SaludCR | ID: biblio-1387690

ABSTRACT

Resumen Introducción: La presencia de microplásticos (MPs, partículas menores a 5 mm) y el incremento de la temperatura en los océanos, vienen generando perturbaciones en la vida marina, que se pueden relacionar con alteraciones en el metabolismo de organismos filtradores, como los mitílidos. Objetivo: Se evalúa el efecto de diferentes temperaturas y concentraciones de MPs sobre la tasa de filtración (TF) de Semimytilus algosus. Métodos: Una muestra de organismos (N = 72) fue expuesta a cuatro temperaturas (17, 20, 23 y 26 °C), y un testigo sin microplásticos (MPs0) y dos concentraciones de MPs (< 125 µm) de 0.125 mg/l (MPs1) y 0.250 mg/l (MPs2), todos en combinación con la microalga Isochrysis galbana (1x106 cel/ml/día) por 21 días. Resultados: A medida que aumentó la concentración de MPs, se redujo la TF de S. algosus. Respecto a la temperatura, durante el día 7 se observó una mayor TF a 23 °C en todos los tratamientos, y para los días 14 y 21 se obtuvieron los menores valores de TF a 23 y 26 °C. La acción conjunta del incremento de temperatura y MPs, afectó negativamente la TF de S. algosus, donde ambos factores ocasionaron el descenso de la TF para todos los tiempos de evaluación. No se registró mortalidad a 17 °C para ningún tratamiento, y en el caso de mitílidos expuestos a MPs1 y temperaturas de 20 y 26 °C se presentó la mayor mortalidad (67 %). Conclusiones: El estudio demuestra el efecto adverso del incremento de temperatura y MPs sobre la TF de S. algosus.


Abstract Introduction: The presence of microplastics (MPs, particles smaller than 5 mm) and the increase in temperature in the oceans, have been generating disturbances in marine life, which can be related to alterations in the metabolism of filter-feeders, such as Mythilids. Objective: The effect of different temperatures and concentrations of MPs on the filtration rate (TF) of Semimytilus algosus is evaluated. Methods: A sample of organisms (N = 72) was exposed to four temperatures (17, 20, 23 and 26 °C), and a control without microplastics (MPs0) and two concentrations of MPs (< 125 µm) of 0.125 mg/l (MPs1) and 0.250 mg/l (MPs2), all in combination with Isochrysis galbana microalgae (1x106 cells/ml/day) for 21 days. Results: As the concentration of MPs increased, the TF of S. algosus decreased. Regarding temperature, during day 7 a higher TF was observed at 23 °C in all treatments, and during days 14 and 21 the lowest TF values were obtained at 23 and 26 °C. The joint action of the increase in temperature and MPs, negatively affected the TF of S. algosus, where both factors caused the decrease in TF for all evaluation times. No mortality was recorded at 17 °C for any treatment, and in the case of mytylids exposed to MPs1 at 20 °C and 26 °C, the highest mortality (67 %) occurred. Conclusions: The study demonstrates the adverse effect of the increase in temperature and MPs on the TF of S. algosus.


Subject(s)
Animals , Bivalvia , Microplastics , Global Warming , Filtration/methods
5.
Arq. bras. med. vet. zootec. (Online) ; 73(3): 711-720, May-June 2021. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1278355

ABSTRACT

This study aimed to evaluate the productive performance, dry matter intake, apparent digestibility and ingestive behavior of feedlot calves fed corn silage from the feed out face of trench silos with different types of sealing. The animals were divided into three treatments with four repetitions: Conventional seal - double-sided polyethylene of 110µm thickness; Double-sided seal - double-sided polyethylene of 200µm thickness; and Double seal - composed of double face polyethylene with a thickness of 80µm superimposed on a polyamide translucent vacuum film with a thickness of 20µm. The use of double face sealing provided 12.63% increase in average daily gain and improved food conversion by 0.62 percentage points. The apparent digestibility of the diet with double-face sealing system silage was 4.30% higher than the diet with double-face sealing silage and 11.00% higher than the diet with conventional sealing silage. It is recommended to use the double face sealing with 200µm polyethylene and double face sealing with 80µm thick polyethylene on top of a 20µm thick polyamide translucent vacuum film.(AU)


Objetivou-se avaliar o desempenho produtivo, o consumo de matéria seca, a digestibilidade aparente e o comportamento ingestivo de novilhos confinados, alimentados com silagem de milho da porção inicial de silos do tipo trincheira, conservada sob distintos tipos de vedação. Os animais foram divididos em três tratamentos, com quatro repetições: vedação convencional - polietileno tipo dupla face, com espessura de 110µm; vedação dupla face - polietileno tipo dupla face, com espessura de 200µm; e dupla vedação - polietileno tipo dupla face, com espessura de 80µm sobreposto a um filme vácuo translúcido de poliamida, com espessura de 20µm. O uso da vedação dupla face proporcionou incremento de 12,63% no ganho de peso médio diário e melhorou em 0,62 ponto percentual a conversão alimentar. A digestibilidade aparente da dieta com silagem do sistema de vedação dupla face foi 4,30% superior em relação à dieta com silagem da dupla vedação e 11,00% superior à dieta com silagem da vedação convencional. Recomenda-se a utilização tanto da vedação dupla face com polietileno de 200µm quanto da dupla vedação com polietileno tipo dupla face, com espessura de 80µm, sobreposto a um filme vácuo translúcido de poliamida com espessura de 20µm.(AU)


Subject(s)
Animals , Male , Cattle , Silage/analysis , Weight Gain , Polyethylene , Eating , Food Storage/methods , Food Packaging/methods
6.
Rev. colomb. quím. (Bogotá) ; 47(1): 34-40, ene.-abr. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-900837

ABSTRACT

Resumen En el ensayo de migración global para empaques plásticos destinados a alimentos grasos se emplea triheptadecanoato de glicerilo (GTM) como patrón interno para la cuantificación de los ésteres metílicos de ácidos grasos (FAMEs) por cromatografía de gases. En este trabajo se evaluaron 3-fenil propanoato de etilo (EFP) y ácido tetradecanóico (AM) como patrones internos alternativos. El uso de AM presentó comportamiento lineal (r > 0,99 y %Sb < 5%), buena precisión intermedia (HORRATr % 0,9) y exactitud (%R % 100,6%). En contraste, la evaluación del EFP, demostró que este no es un patrón interno adecuado para la cuantificación de FAMEs. De otra parte, se evaluó estadísticamente que no hay diferencias significativas en el cálculo de la migración global a partir de FAMEs cuantificados usando como patrón interno GTM o AM, mientras que el uso de EFP sí presenta diferencias significativas.


Abstract In the global migration test for plastic packaging intended for fatty foods, glyceryl triheptadecanoate (GTM) is used as the internal standard for the quantification of fatty acid methyl esters (FAMEs) by gas chromatography. In this work, ethyl 3-phenyl propanoate (EFP) and tetradecanoic acid (AM) were evaluated as alternative internal standards The use of AM presented linear behavior (r > 0.99 and %Sb < 5%), good intermediate precision (HORRATr % 0.9), and accuracy (%R % 100.6%). In contrast, the evaluation of EFP demonstrated that this is not an adequate internal standard for the quantification of FAMEs In addition, it was statistically evaluated that there are no significant differences in the calculation of the global migration from FAMEs quantified using either GTM or AM as internal standards, but the use of EFP presents significant differences.


Resumo No ensaio de migração global para embalagens plásticas destinadas aos alimentos gordurosos, é usado o triheptadecanoato de glicerina (GTM) como padrão interno para a quantificação dos ésteres metílicos de ácidos gordos (FAMEs) mediante cromatografia em fase gasosa. Neste papel foram avaliados 3-fenil propanoato de etilo (EFP) e ácido tetradecanóico (AM) como padrões internos alternativos O (AM) apresentou comportamento linear (r > 0,99 e %Sb < 5%), boa precisão intermédia (HORRATr % 0,9) e precisão (%R % 100,6%). Em contraste, a avaliação do (EFP), mostrou que este não é um padrão interno adequado para a quantificação de FAMEs Por outro lado, uma avaliação estatística indicou que não há diferenças significativas no cálculo da migração global de FAMEs quantificadas utilizando como padrão interno GTM ou AM, em contrapartida o uso do EFP apresenta diferenças significativas.

7.
Rev. Inst. Adolfo Lutz ; 77: e1743, 2018. tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1489576

ABSTRACT

O Instituto Nacional de Controle de Qualidade em Saúde é uma unidade de referência no controle da qualidade em bolsas de sangue. A legislação vigente que descreve este controle é a RDC n° 35/2014 da Agência Nacional de Vigilância Sanitária/Ministério da Saúde, que substituiu a Portaria SVS/MS n° 950/1998 (Secretaria de Vigilância Sanitária/Ministério da Saúde). Os objetivos deste estudo foram avaliar os avanços técnico-científicos no controle da qualidade e propor novas metodologias. Primeiramente, foram comparadas as metodologias e as técnicas recomendadas, para, em seguida, apresentar novos estudos. Na comparação, foram observados os avanços referentes à preocupação da manutenção das colunas cromatográficas e reprodutibilidade de resultados. As metodologias foram desenvolvidas, otimizadas e validadas buscando-se eficiência e robustez. Das onze metodologias, cinco foram alteradas e discutidas neste estudo. Para nova atualização da legislação, estão em tramitação o desenvolvimento de uma metodologia para determinação de teor de citrato e fosfato, avanços em estudos do pH, além de duas metodologias propostas para determinação do principal contaminante. Este estudo apresentou a evolução nos parâmetros da qualidade e evidenciou a importância do Instituto como ente do Sistema Nacional de Vigilância Sanitária e na atualização das questões regulatórias.


The National Institute of Health Quality Control is a reference unit for the quality control of bloodcollecting bags. The current legislation that describes this control is RDC No 35/2014 of National Health Surveillance Agency/Ministry of Health, which replaced the Order SVS/MS N° 950/1998 (Secretariat of Health Surveillance/Ministry of Health). The objectives of this study were to evaluate the technical-scientifical advances in the quality control and to propose the new methodologies. Firstly, the recommended methodologies and techniques were compared; then the new studies were presented. In the comparison study, the progresses were observed regarding the maintenance of the chromatographic columns and the reproducibility of results. The methodologies were developed, optimized and validated looking for the efficiency and robustness. Of eleven methodologies, five were changed and they were discussed in this study. For the further legislation updating, the development of a methodology for determining citrate and phosphate contents, the advances in pH studies, and besides the two proposed methodologies for detecting the main contaminant are underway. This study presented the evolution in the quality parameters and evidenced the importance of Institute as part of the National Sanitary Surveillance System and in the regulatory issues updating.


Subject(s)
Plastic Bags for Blood Preservation , Quality Control , Medical Device Legislation , Brazil
8.
Rev. Inst. Adolfo Lutz (Online) ; (77): 1-9, 2018. tab
Article in Portuguese | LILACS, SES-SP | ID: biblio-1052718

ABSTRACT

O Instituto Nacional de Controle de Qualidade em Saúde é uma unidade de referência no controle da qualidade em bolsas de sangue. A legislação vigente que descreve este controle é a RDC n° 35/2014 da Agência Nacional de Vigilância Sanitária/Ministério da Saúde, que substituiu a Portaria SVS/ MS n° 950/1998 (Secretaria de Vigilância Sanitária/Ministério da Saúde). Os objetivos deste estudo foram avaliar os avanços técnico-científicos no controle da qualidade e propor novas metodologias. Primeiramente, foram comparadas as metodologias e as técnicas recomendadas, para, em seguida, apresentar novos estudos. Na comparação, foram observados os avanços referentes à preocupação da manutenção das colunas cromatográficas e reprodutibilidade de resultados. As metodologias foram desenvolvidas, otimizadas e validadas buscando-se eficiência e robustez. Das onze metodologias, cinco foram alteradas e discutidas neste estudo. Para nova atualização da legislação, estão em tramitação o desenvolvimento de uma metodologia para determinação de teor de citrato e fosfato, avanços em estudos do pH, além de duas metodologias propostas para determinação do principal contaminante. Este estudo apresentou a evolução nos parâmetros da qualidade e evidenciou a importância do Instituto como ente do Sistema Nacional de Vigilância Sanitária e na atualização das questões regulatórias. (AU)


The National Institute of Health Quality Control is a reference unit for the quality control of bloodcollecting bags. The current legislation that describes this control is RDC No 35/2014 of National Health Surveillance Agency/Ministry of Health, which replaced the Order SVS/MS N° 950/1998 (Secretariat of Health Surveillance/Ministry of Health). The objectives of this study were to evaluate the technical-scientifical advances in the quality control and to propose the new methodologies. Firstly, the recommended methodologies and techniques were compared; then the new studies were presented. In the comparison study, the progresses were observed regarding the maintenance of the chromatographic columns and the reproducibility of results. The methodologies were developed, optimized and validated looking for the efficiency and robustness. Of eleven methodologies, five were changed and they were discussed in this study. For the further legislation updating, the development of a methodology for determining citrate and phosphate contents, the advances in pH studies, and besides the two proposed methodologies for detecting the main contaminant are underway. This study presented the evolution in the quality parameters and evidenced the importance of Institute as part of the National Sanitary Surveillance System and in the regulatory issues updating.


Subject(s)
Quality Control , Social Control, Formal , Blood Specimen Collection , Plastic Bags for Blood Preservation
9.
Ciênc. rural (Online) ; 47(10): e20160991, 2017. tab, graf
Article in English | LILACS | ID: biblio-1044877

ABSTRACT

ABSTRACT: The objective of the present study was to evaluate the influence of different plastic covers on microclimate and cherry tomato yield in greenhouses. The experiments were carried out in Piracicaba, state of São Paulo (Brazil), during three growing periods (2008/2009/2010). A greenhouse was divided in: Environment I (EI) - covered with plastic film anti-UV and thermo-reflective shading screen, and Environment II (EII) - covered with diffusive plastic film; monitored with automatic weather sensors; and cultivated with cherry tomato ('Sweet Grape' and 'Sweet Million'). Use of diffusive plastic in greenhouses provides a better inside distribution of solar energy without causing major changes in air temperature and relative humidity, resulting in higher yield (kg plant-1), fruits quantity (number plant-1) and fruits average weight than those obtained under thermo-reflective shading screen.


RESUMO: O objetivo do presente estudo foi avaliar a influência de diferentes coberturas plásticas no microclima e rendimento do tomate cereja em casa-de-vegetação. Os experimentos foram realizados em Piracicaba, Estado de São Paulo, durante três períodos de produção (2008/2009/2010). A casa-de-vegetação foi dividida em Ambiente I (EI) - coberto com filme plástico anti-UV e tela de sombreamento termo-refletora, e Ambiente II (EII) - coberto com filme plástico difusor; monitorados com sensores meteorológicos automáticos; e cultivados com tomate cereja ('Sweet Grape' e 'Sweet Million'). O uso do plástico difusor em casas-de-vegetação proporcionou melhor distribuição da energia solar sem causar grandes mudanças na temperatura e umidade relativa do ar, resultando em maiores rendimento (kg planta-1), quantidade de frutos (número planta-1) e peso médio dos frutos do tomateiro, em comparação ao ambiente coberto com tela termo-refletora.

10.
Rev. luna azul ; 45: [150]-[170], 2017.
Article in Spanish | LILACS | ID: biblio-997425

ABSTRACT

Con base en trabajos de carácter cualitativo y con enfoque de investigación acción participación IAP, se diseñó y se pusieron en funcionamiento varias obras arquitectónicas en Manizales, Marquetalia, Pácora, Pensilvania, Samaná y Chinchiná (Caldas), no solo de beneficio urbanístico, sino ambiental y social. Se logró que las comunidades se involucraran y participaran de manera integral a través de sus familias, lo cual garantizó la pertenencia y el cuidado posterior, logrando a su vez, muy buenas relaciones entre ellos y las diferentes entidades que apoyaron el proyecto.


Several architectural constructions, based on work of a qualitative nature and applying an action research approach IAP, were designed and put into operation in Manizales, Marquetalia, Pácora, Pensilvania, Samaná and Chinchiná (Caldas) not only for the urban benefit, but also for the environmental and social benefit. It was possible for communities to become involved and participate in a comprehensive manner through their families which guaranteed the sense of belonging and the subsequent care, achieving in turn very good relations between the community and the different entities that supported the project.


Subject(s)
Community Participation , Conservation of Natural Resources
11.
Rev. bras. cir. plást ; 28(4): 679-683, july-sept. 2013.
Article in English | LILACS | ID: lil-779147

ABSTRACT

Informed consent is an indispensable tool in the doctorpatient relationship. Aims broadly and unrestrictedly clarify the patient about the procedure, which he/she will be submitted, including all stages of treatment and possible complications. As for the professional who will perform the procedure it's importance goes beyond the precise information to the patient, and also relevance in the legal scope for any grievances that may arise from the committed act. However for the purpose of consent is reached, one should do it in a way in which the physician has the conviction that his informations and explanations about all stages of treatment were in fact understood by the patient. Method: In order to confirm the transfer of information for the informed consent in an objective manner the authors have developed a method using a test administered to the patient after the clarification on the procedure Results: We observed a greater satisfaction by patients regarding explanations because they felt more secure about the treatment's knowledge to be carried out, taking the chance of further clarification if necessary. Conclusions: This model of consent present itself as evidence that the information about the procedure was conveyed unequivocally, ensuring tranquility and safety for the patient and the professional...


O consentimento informado é uma ferramenta indispensável na relação médico-paciente. Tem como objetivo o esclarecimento amplo e irrestrito pelo paciente a respeito do procedimento ao qual será submetido, incluindo todas as etapas do tratamento, bem como as possíveis complicações. Já para o profissional que executará o procedimento, sua importância vai além da informação precisa ao paciente, tendo também relevância no escopo jurídico por eventuais insatisfações que possam advir do ato praticado. Contudo, para que o objetivo do consentimento seja atingido, há de se fazê-lo de uma forma na qual o médico tenha convicção de que suas informações e explicações sobre todas as etapas do tratamento foram de fato compreendidas pelo paciente. Método: Com o objetivo de confirmar a transferência de informação do consentimento informado de forma objetiva, os autores desenvolveramum método que utiliza um teste aplicado ao paciente após os esclarecimentos sobre o procedimento. Resultados: Foi observada satisfação maior pelos pacientes, pois, estes se sentiram mais seguros quanto ao entendimento das explicações realizadas pelo médico, tendo a chance de novos esclarecimentos caso necessário, eliminando a alegação de desconhecimento do ato a ser praticado, inclusive provando de forma objetiva, na possibilidade de demanda judicial, a transferência inequívoca de informação. Conclusão: Este modelo de consentimento é uma opção mais didática no esclarecimento de dúvidas pelos pacientes, além de eliminar a dúvida do profissional em relação à compreensão que o paciente teve de suas explicações sobre o procedimento a ser realizado...


Subject(s)
Humans , Informed Consent , Mental Competency , Surgery, Plastic , Therapeutics , Diagnostic Techniques and Procedures , Methods , Patient Satisfaction , Patients
12.
Rev. colomb. ciencias quim. farm ; 39(2): 149-167, dic. 2010. tab, graf
Article in Spanish | LILACS | ID: lil-597435

ABSTRACT

En este trabajo se evaluaron las tres características fundamentales de desempeño que debe cumplir un envase: protección, funcionalidad y motivación. Para ello, se estudiaron y evaluaron una serie de pruebas reportadas nacional e internacionalmente. Las diferentes pruebas se clasificaron en dos grandes grupos: pruebas físicas y pruebas fisicoquímicas; por otro lado, las pruebas biológicas que son fundamentales para la evaluación de la calidad de estos materiales no están incluidas en el protocolo propuesto, puesto que no se consideran pruebas de control de calidad de rutina. Como resultado de su evaluación experimental, se desarrolló un protocolo unificado y una guía de análisis para el control de calidad fisicoquímico de rutina de los envases y materiales de plástico.


This work evaluated the three fundamental characteristics of performance that must fulfill a package: Protection, functionality and motivation. For it, a series of tests reported at national and international level were evaluated. The tests were classified in two great groups: Physical tests and physical-chemicals tests; in the other hand, the biological tests used to evaluate quality of this kind of materials are not included in the proposed protocol because this quality control test are not considered currently. As resulting from its experimental evaluation, it was developed a unified protocol and a guide for routine quality control test of the packages and plastic material.


Subject(s)
Quality Control , Laboratory and Fieldwork Analytical Methods , Drug Packaging
13.
Dental press j. orthod. (Impr.) ; 15(2): 82-86, mar.-abr. 2010. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-552086

ABSTRACT

OBJETIVO: a finalidade deste estudo in vitro foi avaliar e comparar a resistência friccional em braquetes de aço inoxidável e de policarbonato compósito amarrados com fio metálico e elastômeros. MÉTODOS: foram utilizados quatro braquetes de aço inoxidável e quatro de policarbonato compósito (PC) para pré-molares levados à máquina universal de ensaio mecânico para a tração de um segmento de fio de aço inoxidável 0,019" x 0,025" na velocidade de 0,5mm/min, com 8mm de deslocamento total. A forma de amarração variou entre as seguintes possibilidades: amarração metálica com pinça de Steiner, metálica com pinça Mathieu, elastômero da marca Morelli e elastômero da marca TP Orthodontics. RESULTADOS E CONCLUSÕES: os módulos elastoméricos geraram mais atrito do que os metálicos e a amarração com pinça Mathieu provocou menor atrito quando comparada a todas as situações avaliadas. Os braquetes de PC geraram menor atrito do que os metálicos, porém, na escolha do material a ser utilizado na clínica, outras variáveis - tais como a resistência ao cisalhamento e à fratura, a estabilidade de cor e a aderência por microrganismos - devem ser consideradas.


OBJECTIVE: This in vitro study evaluated and compared the frictional resistance of stainless steel and polycarbonate (PC) composite brackets tied with metal wire and elastomeric ligation. METHODS: Four stainless steel and four polycarbonate composite brackets for premolars were placed in a universal testing machine for the traction of a piece of 0.019 x 0.025-in wire at 0.5 mm/min and total displacement of 8 mm. Ligations were performed according to the following alternatives: metal ligation with Steiner tying pliers; metal ligation using Mathieu tying pliers; MorelliÕ elastomeric ligation; and TP OrthodonticsÕ elastomeric ligation. RESULTS AND CONCLUSIONS: Elastomeric modules generated more friction than the metal ligations, and the ligation with the Mathieu tying pliers caused less friction than all the other conditions under study. PC brackets generated less friction than metal brackets, but the choice of material to be used in clinical conditions should take into consideration other variables, such as resistance to shearing and to fractures, as well as color stability and microorganism adherence.


Subject(s)
Orthodontic Brackets , Orthodontic Wires , Friction , Materials Testing
14.
Neotrop. entomol ; 38(6): 883-884, Nov.-Dec. 2009. ilus
Article in English | LILACS | ID: lil-537418

ABSTRACT

O artigo descreve a construção de um novo aparato simples, para o armazenamento e transporte de tabanídeos vivos durante as coletas realizadas em campo, evitando a perda de espécimes.


The article describes the construction of a simple new device, for the storage of live tabanids during field collections and their transportation to the laboratory, avoiding the loss of specimens.


Subject(s)
Animals , Diptera , Entomology/instrumentation
15.
Rev. bras. anal. clin ; 34(1): 11-13, 2002. tab
Article in Portuguese | LILACS | ID: lil-519734

ABSTRACT

Devido à tendência das plaquetas em aderirem nas superfícies estranhas, além da facilidade destas em aglutinarem e desintegrarem, contagem de plaquetas realizada por método manual apresenta certa dificuldade operacional, estando assim sujeita a resultados errôneos. Presente estudo teve como finalidade, verificar o efeito dos materiais mais comumente utilizados na colheita e diluição das amostras sangüíneas, sobre plaquetometria. Foram analisadas amostras de sangue de 18 indivíduos adultos, colhidas simultaneamente em recipientes de vidro e de plástico contendo EDTA 10%. Diluição destas amostras foram realizadas em tubos de plástico e vidro com oxalato de amônio 1% e a contagem realizada em câmara espelhada de Neubauer. Resultados apontadaram que, faixas plaquetárias obtidas de sangue submetido a diferentes tratamentos não apresentaram diferenças estatisticamente significativas, indicando por conseguinte que, tanto vidro quanto plástico podem ser utilizados sem restrições para realização deste exame.


Subject(s)
Humans , Adult , Platelet Count/instrumentation
16.
Yonsei Medical Journal ; : 1-5, 1983.
Article in English | WPRIM | ID: wpr-63734

ABSTRACT

In a previous report, it was felt that the rat tumor cell line, T-333, was a mixture of heterogeneous cells with different characteristics with respect to karyotype, tumorigenicity, and response to Rolls Sarcoma virus (RSV) infection. These characteristics of hetero-geneous cell subpopulations could be selected by use of different culture substrates. In this experiment, diversity of the cells in response to complement mediated cytolysis employing syngeneic rat anti-sera was studied. More than 50% of the glass grown cells were lysed while only 19% of the plastic grown cells were lysed by the specific immune sera of syngeneic rats. This finding suggests that growth in plastic culture wares selects cells with resistance to complement mediated cytolysis. It seems likely that the previously reported enhanced tumorigenicity of plastic grown T-333 cells is due to clonal selection of cell subpopulations which can better tolerate at least one arm of the in vivo immune surveillance system.


Subject(s)
Rats , Animals , Cells, Cultured , Cytotoxicity, Immunologic , Neoplasms, Experimental/immunology , Plastics , Rats, Inbred Strains
17.
Rev. Inst. Adolfo Lutz ; 43(1/2): e36804, 1983. ilus
Article in Portuguese | LILACS, ColecionaSUS, SES-SP, CONASS, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-55427

ABSTRACT

Foram analisados 138 artigos de uso infantil que normalmente são levados à boca compreendendo: chupetas, mordedores, mamadeiras e seus acessórios, com a finalidade de verificar se são próprios para os fins a que se destinam, do ponto de vista de sua segurança e quanto à migração de substâncias nocivas à saúde. Constatou-se que a grande maioria destes artigos é imprópria. Na ausência de uma norma na legislação brasileira para estes artigos, estabeleceu-se, neste trabalho, uma baseada na legislação para embalagens de alimentos, com algumas alterações. Enfatiza-se neste estudo a necessidade de uma normalização geral pelos órgãos competentes do Ministério da Saúde (AU).


Subject(s)
Humans , Infant , Quality Control , Rubber , Cadmium , Pacifiers , Lead
SELECTION OF CITATIONS
SEARCH DETAIL